korg msk2xr editor section locks

Korg MS2KxR Chapter 4 – Main Functions

User Manuals Knowledge Level

Everything you need to know about our product install, setup steps, configuration and usage of various features

Custom Added Functions

Our plug-in includes a lot of custom added functions as requested by the users.

In this part we will walk you through each of the functions and how they can improve your workflow.

USER INTERFACE SIZE

You can adjust the plug-in user interface size with * 0,75 / * 1,25 zoom function. Click * 1,00 [1] in the plug-in and choose a different size. Note that our graphics are not yet vector based, which means the plug-in will zoom the graphics making them a bit blurry if I may say so.

korg msk2xr editor ui size

MS2KxR Editor User Manual – User Interface Size

Basic user interface size is 1500 pixels by 667 pixels which is more than enough for modern setups.

Note #1: You must reload your project / session in order to reload the plug-in graphics with new size option.

USER INTERFACE SCHEME

You can choose from different user interface scheme that suits your setup. This setting is saved with DAW project data, per project.

  • Normal – Replicates the Original MS2000 color scheme.
  • Black – MS2000 Black Edition.
korg msk2xr editor ui scheme

MS2KxR Editor User Manual – Select UI Scheme

Once User Interface Scheme [1] is chosen, plug-in Control Display [2] reminds you to reload you session or if the plug-in instance is new, remove and reload the plug-in.

korg msk2xr editor ui scheme reminder

MS2KxR Editor User Manual – Reload session or plug-in instance!

 
korg msk2xr editor v208 green

MS2KxR User Manual – Green MS2000-like Scheme

korg msk2xr editor v208 black

MS2KxR User Manual – Black MS2000-like Scheme

Note #1: You must reload your project / session in order to reload the plug-in graphics with new skin option.

MASTER KEYBOARD SWITCH (deprecated)

Always keep it Disabled. This is deprecated function and no longer needed. 😆 We will remove this function and UI elements in the upcoming release later on.

GLOBAL SETTINGS

Click GLOBAL SETTINGS [1] button to open Global settings window. From this view you can access some of the MS2000/R System Settings and modify them as needed.

korg msk2xr editor global settings toggle

MS2KxR Editor User Manual – Global Settings Button

Settings Expanded in image below

korg msk2xr editor global settings view

MS2KxR Editor User Manual – Global Settings Toggled On

Global settings can not be viewed while Librarian is toggled on.

RANDOMIZE DATA

With RANDOMIZE [1] button, you can trigger single timbre randomizing process.

Randomizer affects both Timbres at the same time!

korg msk2xr editor randomize

MS2KxR Editor User Manual – Randomize Button

TIP #2: To make the most out of Randomizer, use Section Locks [1] in conjuction with Randomizer to get better results. i.e. If your randomized Patch has a great AMP Envelope & Oscillator setting, toggle on the Section Lock for those sections in order to prevent them being randomized! Read more about the Section Locks further below.

korg msk2xr editor locked sections

MS2KxR Editor User Manual – Locked Sections

SECTION LOCKS

We added functionality to lock certain sections of the plug-in to prevent changes up on timbre program changes. If you find a perfectly adjusted filter or lfo modulation you can lock the section to keep those settings while browsing other patches.

You are able to lock any of the sections which has the LOCK [1-19] symbol in it

korg msk2xr editor section locks

MS2KxR Editor User Manual – Section Locks

RELEASE ALL LOCKS [1] button allows you to release all of the locks with one click. This is ideal if you have overlooked your layers and data is being transmitted back and forth even if you don’t want that.

 

korg msk2xr editor release all locks

MS2KxR Editor User Manual – Release All Locks

Note #1 While you have sections locked, there will double the amount of SysEx traffic in the MIDI stream due to the fact that the plug-in has to send the ”locked” info back to hardware after the patch is requested. If you scroll patches from librarian, then the data stream is normal.

TIMBRE SELECT

Timbre Select [1] button is normal MS2000/R function, which will change the current Timbre of the synthesizer. Based on the currently set Timbre, data from the plug-in user interface will be sent to it. i.e. if you move Filter Cutoff from the UI while Timbre 1 is selected, then Filter Cutoff in Timbre 1 of the synth will change.

 

korg msk2xr editor timbre select

MS2KxR Editor User Manual – Timbre Select

TIMBRE LINK

Timbre LINK [1] button is normal MS2000/R function as well, which will LINK the Timbres of the synthesizer. You can play both timbres at the same time or create wide sounds with dual timbre setup.

korg msk2xr editor timbre link large

MS2KxR Editor User Manual – Timbre LINK Toggle

REQUEST DATA ON PROGRAM CHANGE

This means that if the plug-in receives program and/or bank change message from MIDI input, plug-in will initiate data request from the MS2000/R to the plug-in user interface.

Inputs valid for this function:

  • Plug-in MIDI In port (Plug-in).
  • DAW gateway (Plug-in).
  • Plug-in Program Change [1] & [2] buttons (*1).
korg msk2xr editor program change

MS2KxR Editor User Manual – Request Data on Program Change

(*1 See below for Program Change Buttons).

LOAD FROM LIBRARY SWITCH

LOAD FROM LIBRARY [1] switch allows you to take control of your library patches with incoming program changes via MIDI or with the plug-in user interface – / + buttons.

korg msk2xr editor load from lib

MS2KxR Editor User Manual – Load data from Library

If the LOAD FROM LIBRARY switch is toggled on and you send a program change message from your master keyboard / controller to the plug-in, it will send the corresponding program from the librarian to the hardware – isn’t that just neat?!

Note #1 Patches are sent to the hardware only to the currently selected slot.

Note #2 If the program change message is received from MIDI channel 4 and you currently have Timbre 1 set to channel 1 and Timbre 2 to channel 2, no action will be taken.

Note #3 If the program change message is received from MIDI channel 1 and both Layers are set to channel 1, no action will be taken. Change the MIDI channel temporarely to different value.

PROGRAM – / + BUTTONS (*1)

– [1] button will change to next program.
+ [2] button will change to previous program.

This will trigger MIDI Out message with appropriate program number.

korg msk2xr editor program change

MS2KxR Editor User Manual – Program Change Buttons

PATCH LIBRARIAN

LIBRARIAN [1] tab allows you to send, request, store and manipulate your patch banks.

Double click any item to send it to currently active timbre. Drag and drop patches from one slot to another and save your custom bank as you go. Rename patches directly in librarian view.

Read more about patch librarian functions in its own section.

 

korg msk2xr editor librarian view

MS2KxR Editor User Manual – Patch Librarian

PATCH NAME DISPLAY

Patch Display [1] will show you the current program name. Click the name field to change the patch name. Data will be sent to the hardware after the name is changed or if it is changed at all.

korg msk2xr editor program name

MS2KxR Editor User Manual – Program Name

NOTE #1: Renaming single patch from the “Control Display” does not change the name in the librarian. If you want to rename librarian items, check further down the manual for librarian functions.

TOTAL RECALL

This is one of the best features we can think about our plug-in, total recall. It does what it says: recalls your saved session data from the plug-in user interface to your synthesizer, without the need of doing it manually! It is all automated, if you have the same MIDI device hooked into your setup as it was when saving the project.

It there are any trouble with the total recall, please check below for further instructions how to Push Data to HW manually.

Possible reasons for failure of total recall are:

1) Your MIDI interface is no longer in the system, or it is hooked into a different USB port.
2) Plug-in update does not fully support the previous version data package. There is a work-around for that as well, so be sure to check out our knowledge base for more details about that.

ABORT PROCESS

Cancel current request / writing task by clicking ABORT PROCESS button, if process is taking too long, or if you get constant MIDI Channel checks while any data request is active.

korg msk2xr editor abort process lib

MS2KxR User Manual – Abort Process in Librarian View

This same button appears next to plug-in control display when Librarian tab is not open.

korg msk2xr editor abort process main

MS2KxR User Manual – Abort Process in Main View

Abort Process button will disappear after plug-in has scanned MIDI Channels and if the request process has timed out.

MOD SEQUENCER LAYER

As you know, MS2000/R in shipped with powerful Mod Sequencer feature. To access these parameters, you need to click the MOD SEQUENCER [1] button.

From this tab, you can manipulate all Mod Sequence parameters available.

korg msk2xr editor mod sequencer

MS2KxR Editor User Manual – Mod Sequencer Editor

Learn more about Mod Sequencer function from the Korg MS2000/R User manual.

Loading patches between different models?

You can load patches created with MS2000 models as well as programs created with Korg microKorg. Some parameters like Mod Sequencer are not available in microKorg and microKorg’s Step Sequencer function is not available in MS2000 models.

In near future, when we finish our Radias Editor, it will be able to open MS2000 and microKorg programs to each timbre individually and timbre stored programs from Radias Editor can be opened with MS2000 Editor.

 